2
USER GUIDE
USER GUIDE
Dim / Mute
When a channel with the monitor mute option congured has PFL selected, the control
room monitors can be set to either dim or mute. If the fader is then opened, the monitors
will mute irrespective of this setting. The red mute LED will still illuminate if the monitors
are set to DIM rather than MUTE on PFL.
Meter Controls
Program / Meters Follow Monitors
The PGM / MFM Button selects whether the meters should display
PGM only or display the selection that is heard in the presenters
headphones. The selection of this button can be locked if required.
This button is illuminated RED if MFM is selected.
PPM / VU
The meters can be congured
to display either PPM or VU. A
red LED is illuminated next to
the currently active scale. The
meter mode is a conguration
option available through SCi
The PPM meters have a 1-7 scale
and will be congured such
that a 1kHz signal, at 0dBu at
the PGM output, will indicate a
meter reading of 4. Each mark
on the PPM scale indicates a
4dB change in signal level.
The VU meter operates between -20 and +3 Volume units and follows the standard
denition for a VU meter. Please see ANSI C16.5-1942, BS 6840 or IEC 60268-17 for more
details.
User Guide – Section 2-5 Output Buses
PGM Output
The PGM output provides stereo balanced XLR outputs. The PGM
Output is used as the main transmission bus. All channels that are on
and faded in are mixed on to this bus.