DMT Presenter Control Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Projetores DMT Presenter Control. DMT Presenter Control User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - User Manual

User ManualVersion 1.5Culture Myograph System Model 202CM

Página 2

10Culture Myograph System Model 202CM Unpacking the Myograph SystemPlease take a few minutes to carefully inspect your new Culture Myograph Syst

Página 3 - Trademarks

11User Manual vers. 1.4 Chapter 1Cable to myo-InterfaceVertical regulation plate for left glass cannulaFixation and longitu-dinal regulation pla

Página 4

Plug for connec-tion of tempera-ture probeLight intensity regulation plugInfrared light scource Zeiss Achromat 10X / 0.25 objectiveLever to fasten cul

Página 5 - Approvals

Chapter 2 - Setting up2.1 The Complete Culture Myograph System – 202CMFigure 2.1 Setting up step by step Note:If you have purchased a computer from DM

Página 6 - Certicate of Conformity

14Culture Myograph System Model 202CM 2.2.1 Setting up the Complete Culture Myograph System 202CMThis section describes how to connect the cable

Página 7 - Contents

2.2.2.1 Software and Picolo Driver Installation Insert the Culture Myograph 202CM installation CD, to install the 202CM Control program for the Heat

Página 8

Click “Install”The 202CM Control program is now installing from the CD.Click “Finish”The installation will now proceed with installation of the Picolo

Página 9 - About this Manual

Ignore the warning.Click “OK”It is recommended to install the software in the default folder.Click “Next”.Setup Type, choose Typical.Click “Next”Click

Página 10 - Unpacking the Myograph System

18Culture Myograph System Model 202CM Click “Yes”The Picolo Frame Grabber is now installing from the CD.The Picolo Frame Grabber is now installe

Página 11 - Chapter 1 - System Overview

It is recommended to install the software in the default folder.Click “Next”Click “Next”Click “Next”The VediView Software package is now installed.Cli

Página 12 - 1.2 DMT Microscope

2Culture Myograph 202CM

Página 13 - Chapter 2 - Setting up

20Culture Myograph System Model 202CM 2.2.2.2 DMT 202CM VCP driver installationConnect the Heat Controller to the computer’s USB port, using a s

Página 14

Note:A sterile micro lter (0.20µm) is connected between the pressure manometer reservoir and the two perfusion reservoirs to prevent contamination of

Página 15

22Culture Myograph System Model 202CM 2.3.3 Setup and Control of Superfusion Flow The superfusion circuit consists of an inow and an outow fro

Página 16 - Culture Myograph 202CM

Chapter 3 - VediView™ Software Manual3.1 Introduction to VediView™VediView™ provides an interface for image analysis of small blood vessels mounted in

Página 17

24Culture Myograph System Model 202CM 3.2 User Interface3.2.1 MenusMenus are located across the top of the VediView™ interface. All the actions

Página 18

3.2.3 ToolbarVediView™ contains a "dockable" tool bar containing buttons with specic icons used as short cuts to various VediView™operation

Página 19

3.2.4 Main WindowThe main window can show any of the graphical displays of the control bars, which are the frame grabber image, data control or analys

Página 20 - 2.3 Experiment Setup

3.2.5 ModalityMany aspects of the VediView™ software layout are similar to standard Windows applications (e.g. Microsoft Ofce). Main menus are availa

Página 21 - 2.2.2 Perfusion Flow Control

28Culture Myograph System Model 202CM All control bars can be “undocked” and re-sized for convenience in a given experiment. Once the control ba

Página 22

3.3.2.1 Displaying ImagesThe real time frame-grabbing mode may be switched on or off by means of the “start/stop display” button or from the pop-up

Página 23 - Chapter 3 - VediView

Culture Myograph System - Model 202CMUser ManualTrademarksPentium is a registered trademark of the Intel Corporation. Windows, Windows 95, Windows 98,

Página 24 - 3.2 User Interface

30Culture Myograph System Model 202CM 3.3.2.6 Distance MeasurementIf the user wishes to measure a distance on the image, VediView™ can supply th

Página 25 - 3.2.3 Toolbar

3.3.3.1 Selecting Data for DisplayThe data control bar can be used to display up to six parameters in the interface. These can be selected from the li

Página 26 - 3.2.4 Main Window

32Culture Myograph System Model 202CM Data logging is not automatic and must be activated by selecting (or creating) a le. Files are chosen by

Página 27 - 3.3 Topics

3.3.4.2 Calibration of Image AnalysisCalibration of image dimensional analysis can be done in sensible units (e.g. microns) dened by the user. To per

Página 28 - 3.3.2 Frame grabber

34Culture Myograph System Model 202CM If the analysis rectangle contains a “valid” vessel but only has the outer edges determined by edge detect

Página 29 - 3.3.2.4 Saving an Image

VediView can analyse vessels positioned in either the vertical or horizontal planes. The congure analysis dialog box can be used to select the appro

Página 30 - 3.3.3 Data

36Culture Myograph System Model 202CM 5. Once the dimensions and units of the calibrated rectangle are correctly entered, click the ”calibr

Página 31 - 3.3.3.4 Data Logging

interface is done through reconguration of the control bars and main window contents. In the example shown in Fig. 3.28 the data control bar has be

Página 32 - 3.3.4 Analysis

38Culture Myograph System Model 202CM 3.6 FAQThere are only six parameters in the graphical display, how do I display other data acquired or cal

Página 33

Chapter 4 - DMT 202CM Control Program4.1 Control of Temperature and Light IntensityIn addition to the VediView™data acquisition and analysis software

Página 34

4Culture Myograph System Model 202CM SafetyThe Culture Myograph System has been designed for use only in teaching and research applications. It

Página 35

Set-temperature:The temperature controller tab is used to adjust the set temperature for each chamber (range: 10 - 450C with 0.10C accuracy). If a tem

Página 36 - 3.5 Customising the Interface

Chapter 5 - Culture Myograph Manual5.1 The Culture Myograph UnitThe culture myograph unit is placed on the DMT microscope as illustrated in Fig. 5.1.

Página 37 - Custom interface set-up

Horizontal Adjustment:Horizontal adjustment is performed as illustrated in Fig. 5.1 and 5.2.Gently loosen the screw xing the chamber and carefully mo

Página 38

5.1.2 Removal and Mounting of Glass Cannulas and ChamberReplacement of glass cannulas and demounting of the culture myograph chamber for sterilisation

Página 39

44Culture Myograph System Model 202CM 5.1.3 Changing O-ringsEach locknut on the culture myograph chamber is equipped with rubber O-rings (ø1.07

Página 40

5.2 The DMT MicroscopeThe DMT microscope is an invert microscope equipped with a Zeiss Achromat 10X / 0.25 objective and build-in CCD camera. The obje

Página 41 - 5.1 The Culture Myograph Unit

5.3 Pressure Regulator The Pressure Regulator is connected to the culture myograph system to generate a pressure on the mounted vessel from the perfus

Página 42 - Horizontal Adjustment Screw

In cases of red or brown discolorations appearing on the chamber sides, the following cleaning procedure will work in most cases:1. Incubate the myog

Página 43 - Lock-screw

48Culture Myograph System Model 202CM Chapter 6 - Myograph Accessories and Spare PartsThis chapter contains a complete list of equipment needed

Página 44 - 5.1.3 Changing O-rings

6.2 Culture Myograph 202CM System AccessoriesThis section contains a list of special accessories available for the Culture Myograph System - Model 202

Página 45 - 5.2 The DMT Microscope

EMC / EMIThis equipment has been tested and found to comply with the limits for a Class B Digital device, pursuant to part 15 of the FCC rules. These

Página 46 - 5.3 Pressure Regulator

50Culture Myograph System Model 202CM Chapter 7 - Getting Started7.1 Dissection Protocol for Small Mesenteric ArteriesThe culture myograph techn

Página 47

51User Manual vers. 1.4 Chapter 76. Use high quality forceps and ocular dissection scissors (see Chapter 6.1) to dissect the vessel segmen

Página 48

52Culture Myograph System Model 202CM • The branch points of arteries are V-shaped whereas those of veins are more U-shaped.• The arterial w

Página 49

53User Manual vers. 1.4 Chapter 79. Clean the artery by removing any remaining adipose or connective tissue. Gently pull away adipose or c

Página 50 - Chapter 7 - Getting Started

54Culture Myograph System Model 202CM 7.2 Mounting Protocol for Small ArteriesThis section shortly describes the basic technique of mounting sm

Página 51

55User Manual vers. 1.4 Chapter 77.3 Buffer Recipes7.3.1 Physiological Saline Solution (PSS)1x PSS (1000ml):Solution 1.Chemical MW (g/mol)

Página 52

56Culture Myograph System Model 202CM 25x Concentrated PSS (1000ml)Solution 1Chemical MW (g/mol) Conc. (mmol/l) Conc. (g/l)NaCl 58

Página 53

Appendix 1 - Terms of WarrantyWarrantyDMT A/S warrants to the original user that myograph systems manufactured by DMT A/S will be free from defects in

Página 54

58Culture Myograph System Model 202CM Appendix 2 - Service CheckA myograph working at optimal performance is extremely important for success whe

Página 55 - 7.3 Buffer Recipes

Appendix 3 - Shipping InstructionsIf the myograph system needs to be sending back for service or repair, please read the following shipping instructio

Página 56

6Culture Myograph System Model 202CM Certicate of ConformityDMT A/S, Skejbyparken 152, 8200 Aarhus N., Denmark, hereby declares its responsibil

Página 57

Appendix 4 - System Specications Chamber Unit:Vessel size: Chamber:Chamber volume: Capillary ports:Superfusion ports:Base window: Chamber material:Ch

Página 58 - Appendix 2 - Service Check

Appendix 5 - Fuse ChangingThe main fuse of the myograph system is placed inside the power inlet on the Heat controller. If the fuse blows it is easily

Página 59

Appendix 6 - VCP – Driver InstallationThe rst time the 202CM Heat Controller and the DMT microscope is connected to the PC the VCP drivers must be in

Página 60

If Windows XP is congured to warn when unsigned (non-WHQL certied) drivers are about to be installed, the following screen will be displayed.Click

Página 61 - Appendix 5 - Fuse Changing

When the drivers for the Heat controller and the microscope are installed the 202CM Controller Software can be opened and connected as described in pa

Página 63

DMT-USA, Inc.P.O. Box 681373Marietta, GA 30068-0023USA Tel.: +1 770 612 8014Fax: +1 678 302 [email protected] or sales@dmt-us

Página 64

7User Manual vers. 1.4 ContentsContentsSafety ...

Página 65

8Culture Myograph System Model 202CM 3.6 FAQ .......

Página 66

About this ManualThis manual contains a complete list of procedures describing how to install, maintain and get started using the Culture Myograph Sys

Comentários a estes Manuais

Sem comentários